16.3-16.4 - Measuring Reaction Rates

16.3-16.4 - Measuring Reaction Rates

Choose a measurable change that follows reaction progress. Compare initial-rate experiments with continuous monitoring, then plan measurements whose controls, resolution and chemical selectivity make the resulting data useful.

Start With The Measurable Change

A student says, "This reaction is fast because it fizzes a lot." That is an observation, but it is not yet rate data. Rate data need a measurable quantity that changes with time and can be linked to the amount or concentration of a reactant or product.

For any rate experiment, ask three questions before naming apparatus:

  1. Which species is changing in a measurable way?
  2. Does the measurement track that species directly, or is it only a proxy?
  3. Can the measurement be repeated often enough without disturbing the reaction?

A good rate technique gives a signal that changes smoothly as the reaction proceeds. The signal might be concentration, absorbance, mass, gas volume, pressure, pH, conductivity or the time taken to reach a fixed visible change.

Chemical change availablePossible rate signalSuitable technique
A coloured reactant is used up, or a coloured product formsAbsorbance changes with concentrationColorimetry
A gas is produced and can escape safelyMass decreases as gas leavesMass-change method on a balance
A gas is produced and can be collectedGas volume increases with timeGas syringe or inverted measuring cylinder
An acid, alkali, oxidising agent or iodine concentration changesAliquots can be analysed chemicallyTitration after sampling and quenching
Ionic concentration changes stronglyConductivity changesConductivity probe
Hydrogen ion concentration changespH changespH meter or pH probe
A precipitate or turbidity appearsLight transmission falls, or a fixed mark disappearsTurbidity/colorimetry or clock-style method

The word "suitable" is doing real work. A method is suitable only if the measurement is connected to the reaction progress, the apparatus has adequate resolution, the reaction can be followed safely, and the data can be processed into a rate or a graph.

Common-error contrast. Do not justify a method only by saying "it is easy to see". A visible change is not automatically quantitative. For example, "the solution turns pale" is weaker than "a colorimeter can record absorbance at regular time intervals, and absorbance is linked to the concentration of the coloured species."

The Named Techniques

You need to select and justify techniques, not just list them. The same reaction may have more than one possible method, but some methods are cleaner than others.

TechniqueHow it obtains rate dataStrong fit when...Main limitations to mention
TitrationRemove small samples at known times, stop or slow the reaction, then titrate to find how much reactant or product is presentThe species can be analysed accurately and the reaction is slow enough for samplingSampling disturbs the mixture; quenching must be effective; endpoint uncertainty affects each data point
ColorimetryMeasure absorbance at regular intervals, often after calibration or using a blankOne reactant or product is coloured and no other species seriously interferes at the chosen wavelengthOnly works well for suitable coloured species; cuvettes must be clean; very dark or very pale solutions give poor precision
Mass changePlace the reaction vessel on a balance and record mass as gas escapesA gas product leaves the apparatus and no important liquid/solid loss occursDraughts, evaporation and splashing can change mass; it does not identify the gas; not suitable if gas is trapped
Volume of gas evolvedCollect gas and record volume with timeA gas product is made and can be collected with minimal loss or dissolutionLeaks, soluble gases, gas syringe friction and temperature/pressure changes affect volume
Other suitable techniquesUse pH, conductivity, pressure, turbidity or spectroscopy as appropriateThe chosen signal changes predictably with reaction progressThe link between signal and concentration must be justified, not assumed

Titration method logic. Titration is useful when concentration cannot be read continuously from the reaction flask. For example, a reaction mixture can be sampled every few minutes, each aliquot can be quenched by cooling, dilution or a stopping reagent, and the remaining reactant can be titrated. The quench step matters because the aliquot must represent the composition at the sampling time, not the composition several minutes later during analysis.

For iodine titration, use IX2+2 SX2OX3X2−→2 IX−+SX4OX6X2−\ce{I2 + 2S2O3^2- -> 2I- + S4O6^2-}: [IX2]=cthioVtitre/(2Vsample)[\ce{I2}]=c_{\mathrm{thio}}V_{\mathrm{titre}}/(2V_{\mathrm{sample}}). Quenching must leave the analysed iodine unchanged. Cooling or dilution may only slow a reaction; verify that continued reaction during analysis is negligible, and account for any dilution when converting the titre to the original sample concentration.

Colorimetry method logic. A colorimeter can provide many data points without removing samples. It is especially powerful when the coloured species is the reactant being used up or the product being formed, because absorbance can be followed against time. If a question asks for a justification, say what is coloured and why the absorbance change tracks the reaction.

Choose a wavelength strongly absorbed by the coloured species and zero the instrument with a solvent/reagent blank that excludes that species. Use clean cuvettes in the same orientation and path length. A calibration series of known concentrations tests the usable linear range; absorbance is proportional to concentration only within that range. Bubbles or turbidity scatter light and can create an unrelated signal.

Gas methods logic. Gas volume and mass change are often alternatives. Gas volume is more direct if the gas can be collected reliably; mass loss is simpler if the gas escapes but harder to use when the mass change is small or the gas is very soluble. Either way, the initial apparatus must be sealed appropriately: a gas syringe setup should be leak-free, while a mass-loss setup must allow gas to leave.

When a balance works

"Use a balance" suits a reaction producing escaping carbon dioxide, not one where all products stay dissolved: the balance method works only if the total measured mass changes. If carbon dioxide escapes, the mass of the apparatus decreases as the reaction proceeds. If all products remain in the flask, atoms have rearranged but the total mass on the balance is essentially unchanged, so the balance gives no useful rate signal.

Initial-Rate Experiments

An initial-rate experiment measures how fast the reaction starts under a chosen set of starting concentrations. Separate experiments are carried out, and in each one the initial concentration of one reagent is changed while the other conditions are kept constant.

The method structure is:

  1. Prepare a mixture with known initial concentrations.
  2. Start timing at the same mixing point.
  3. Measure a small early change.
  4. Repeat with one initial concentration changed.
  5. Keep total volume, temperature and other reagent concentrations controlled.

Concentration after mixing

cmixed=cstock VstockVtotalc_{\mathrm{mixed}} = \frac{c_{\mathrm{stock}}\,V_{\mathrm{stock}}}{V_{\mathrm{total}}}

Both volumes in the same unit; concentrations in mol dm−3\mathrm{mol\,dm^{-3}}. The amount of solute is unchanged by adding water.

For example, 15.0 cm315.0\,\mathrm{cm}^{3} of 0.200 mol dm−30.200\,\mathrm{mol\,dm}^{-3} solution made up to 50.0 cm350.0\,\mathrm{cm}^{3} gives 0.0600 mol dm−30.0600\,\mathrm{mol\,dm}^{-3}.

The key idea is that the reaction is judged near the beginning, before concentrations have changed very much. This is why the data can later be used to connect initial concentration to initial rate.

Clock reactions as an approximation. In a clock reaction, the measured value is usually the time taken for a fixed visible change to occur, such as a sudden colour change or the appearance of enough precipitate to obscure a mark. If the visible change always happens after the same small amount of product has formed, then:

Clock reactions

initial rate∝1t\text{initial rate} \propto \frac{1}{t}

tt = time to the fixed visible endpoint, in s. Valid only when the endpoint represents the same small extent of reaction in every run.

That approximation is valid only when the endpoint represents the same small extent of reaction each time. It is not valid if the endpoint amount changes between runs or if the reaction has already consumed a large fraction of a reactant before the clock change appears.

Worked example. A reaction forms a cloudy precipitate. The endpoint is defined as the time when a printed cross under the flask can no longer be seen. A student changes the initial concentration of reactant A, keeps the total volume constant by adding water, keeps temperature constant, and measures the time to the same visual endpoint.

Continue this lesson.

You’re previewing NovaLearn without an account. Create a free account to read the rest.

Create free account